Heavy Duty Silent Diesel Generator
A heavy duty silent diesel generator is a high-output power generation system designed for construction sites, factories, commercial facilities, data centers, mining operations, and backup power applications where stable electricity and controlled operating noise are required.
The heavy duty silent diesel generator is centered around a diesel engine, an alternating current generator, an intelligent control system and a soundproof enclosure. It converts diesel into continuous electrical energy, and the enclosure can effectively reduce the engine and exhaust noise in the installation area. For users who purchase generator sets, the key purchasing points include rated output power, engine configuration, fuel consumption rate, noise level, voltage, control functions, enclosure design and long-term after-sales service.
|
Model |
Rate Power kW |
Rate Power kVA |
Current (A) |
Engine Model |
Engine power |
Cylinder No. |
Bore*Stroke (mm) |
Open Type Size (L*W*H mm) |
Open Type Weight (kg) |
|
MST-30YII |
30 |
37.5 |
54 |
YC4D55-B21 |
40 |
4/L |
102*118 |
1800*750*1200 |
900 |
|
MST-40YII |
40 |
50 |
72 |
YC4D60-D25 |
44 |
4/L |
102*118 |
1800*750*1200 |
920 |
|
MST-50YII |
50 |
62.5 |
90 |
YC4D90Z-D25 |
60 |
4/L |
102*118 |
1800*750*1200 |
920 |
|
MST-60YII |
60 |
75 |
108 |
YC4A100Z-D25 |
70 |
4/L |
110*125 |
2250*800*1300 |
1200 |
|
MST-80YII |
80 |
100 |
144 |
YC4A140L-D25 |
100 |
4/L |
110*125 |
2080*940*1390 |
1250 |
|
MST-100YII |
100 |
125 |
180 |
YC4A180L-D20 |
120 |
4/L |
108*132 |
2250*950*1420 |
1300 |
|
MST-100YII |
100 |
125 |
180 |
YC6B180L-D20 |
120 |
6/L |
108*132 |
2350*950*1420 |
1450 |
|
MST-120YII |
120 |
150 |
216 |
YC6B205L-D20 |
138 |
6/L |
108*125 |
2500*850*1300 |
1450 |
|
MST-140YII |
140 |
175 |
252 |
YC6A245L-D21 |
165 |
6/L |
108*132 |
2550*950*1350 |
1465 |
|
MST-200YII |
200 |
250 |
360 |
YC6MK35OL-D20 |
235 |
6/L |
123*145 |
2930*1120*1600 |
1990 |
|
MST-250YII |
250 |
312.5 |
450 |
YC6MK420L-D20 |
281 |
6/L |
123*145 |
3010*1100*1600 |
2200 |
|
MST-300YII |
300 |
375 |
540 |
YC6MJ500L-D21 |
334 |
6/L |
123*145 |
3050*1100*1700 |
2570 |
|
MST-360YII |
360 |
450 |
648 |
YC6T600L-D22 |
401 |
6/L |
145*165 |
3500*1280*1800 |
3200 |
|
MST-400YII |
400 |
500 |
720 |
YC6T660L-D20 |
441 |
6/L |
145*165 |
3500*1440*1800 |
3800 |
|
MST-40YIII |
40 |
50 |
72 |
YC4D80-D34 |
53 |
4/L |
102*118 |
1850*750*1200 |
800 |
|
MST-50YIII |
50 |
62.5 |
90 |
YC4D90-D34 |
60 |
4/L |
102*118 |
1920*880*1200 |
900 |
|
MST-60YIII |
60 |
75 |
108 |
YC4D105-D34 |
70 |
4/L |
110*125 |
1950*850*1200 |
950 |
|
MST-80YIII |
80 |
100 |
144 |
YC4D140-D31 |
100 |
4/L |
108*115 |
2200*850*1200 |
1100 |
|
MST-90YIII |
90 |
112.5 |
162 |
YC4D155-D31 |
103 |
4/L |
108*115 |
2300*900*1500 |
1200 |
|
MST-100YIII |
100 |
125 |
180 |
YC4A165-D30 |
110 |
4/L |
108*132 |
2300*900*1500 |
1250 |
Key Specifications
|
Item |
Configuration |
|
Generator Type |
Silent Diesel Generator |
|
Power Range |
Customizable according to project requirements |
|
Fuel |
Diesel |
|
Frequency |
50 Hz / 60 Hz |
|
Voltage |
Customizable |
|
Phase |
Single Phase / Three Phase |
|
Cooling |
Water-Cooled |
|
Starting System |
Electric Start |
|
Controller |
Intelligent Digital Controller |
|
Enclosure |
Sound-Attenuated Steel Canopy |
|
Application |
Prime / Standby Power |
|
Output Connection |
Customized to project requirements |



Why the Silent Enclosure Matters
A diesel engine produces mechanical vibration, combustion noise, cooling-fan noise, and exhaust noise during operation.
The enclosure addresses these sources through acoustic insulation, airflow channels, vibration isolation, and controlled air intake and exhaust paths.
For a factory installed close to production offices, for example, reducing sound transmission can make a practical difference to the working environment. The operator hears the steady engine rhythm rather than the sharp mechanical noise of an exposed engine, while the steel canopy provides protection for the internal components.
The enclosure also protects the power system from dust, rain, and other outdoor conditions when the specified configuration is selected.
Available Configuration Options May Include
Engine:
Different diesel engine brands and power ratings
Alternator:
Multiple alternator configurations according to output requirements
Controller:
Digital control and monitoring systems
Fuel Tank:
Standard or extended-capacity designs
Canopy:
Silent, weather-resistant enclosure
Transfer System:
ATS configuration for automatic backup switching
Output:
Customized voltage, frequency, and connection requirements
Mobility:
Fixed, trailer-mounted, or project-specific configurations
For buyers preparing an RFQ, the following information helps suppliers select the correct configuration:
- Required running load in kW or kVA
- Motor starting loads
- Prime or standby operation
- 50 Hz or 60 Hz frequency
- Required output voltage
- Single-phase or three-phase supply
- Indoor or outdoor installation
- Required noise limit
- Fuel tank operating time
- Ambient temperature and installation altitude
If you want to know more about the heavy duty silent diesel generator, please contact us. We also provide support for foreign trade order coordination and offer prompt delivery.

Hot Tags: heavy duty silent diesel generator, China heavy duty silent diesel generator manufacturers, suppliers, factory