Heavy Duty Silent Diesel Generator

Heavy Duty Silent Diesel Generator

A heavy duty silent diesel generator is a high-output power generation system designed for construction sites, factories, commercial facilities, data centers, mining operations, and backup power applications where stable electricity and controlled operating noise are required.
The heavy duty silent diesel generator is centered around a diesel engine, an alternating current generator, an intelligent control system and a soundproof enclosure. It converts diesel into continuous electrical energy, and the enclosure can effectively reduce the engine and exhaust noise in the installation area.
Share to
Send Inquiry
Description
Technical Parameters

Heavy Duty Silent Diesel Generator

 

 

A heavy duty silent diesel generator is a high-output power generation system designed for construction sites, factories, commercial facilities, data centers, mining operations, and backup power applications where stable electricity and controlled operating noise are required.

 

The heavy duty silent diesel generator is centered around a diesel engine, an alternating current generator, an intelligent control system and a soundproof enclosure. It converts diesel into continuous electrical energy, and the enclosure can effectively reduce the engine and exhaust noise in the installation area. For users who purchase generator sets, the key purchasing points include rated output power, engine configuration, fuel consumption rate, noise level, voltage, control functions, enclosure design and long-term after-sales service.

 

Model

Rate Power

kW

Rate Power

kVA

Current

(A)

Engine Model

Engine

power

Cylinder

No.

Bore*Stroke

(mm)

Open Type Size

(L*W*H mm)

Open Type Weight

(kg)

MST-30YII

30

37.5

54

YC4D55-B21

40

4/L

102*118

1800*750*1200

900

MST-40YII

40

50

72

YC4D60-D25

44

4/L

102*118

1800*750*1200

920

MST-50YII

50

62.5

90

YC4D90Z-D25

60

4/L

102*118

1800*750*1200

920

MST-60YII

60

75

108

YC4A100Z-D25

70

4/L

110*125

2250*800*1300

1200

MST-80YII

80

100

144

YC4A140L-D25

100

4/L

110*125

2080*940*1390

1250

MST-100YII

100

125

180

YC4A180L-D20

120

4/L

108*132

2250*950*1420

1300

MST-100YII

100

125

180

YC6B180L-D20

120

6/L

108*132

2350*950*1420

1450

MST-120YII

120

150

216

YC6B205L-D20

138

6/L

108*125

2500*850*1300

1450

MST-140YII

140

175

252

YC6A245L-D21

165

6/L

108*132

2550*950*1350

1465

MST-200YII

200

250

360

YC6MK35OL-D20

235

6/L

123*145

2930*1120*1600

1990

MST-250YII

250

312.5

450

YC6MK420L-D20

281

6/L

123*145

3010*1100*1600

2200

MST-300YII

300

375

540

YC6MJ500L-D21

334

6/L

123*145

3050*1100*1700

2570

MST-360YII

360

450

648

YC6T600L-D22

401

6/L

145*165

3500*1280*1800

3200

MST-400YII

400

500

720

YC6T660L-D20

441

6/L

145*165

3500*1440*1800

3800

MST-40YIII

40

50

72

YC4D80-D34

53

4/L

102*118

1850*750*1200

800

MST-50YIII

50

62.5

90

YC4D90-D34

60

4/L

102*118

1920*880*1200

900

MST-60YIII

60

75

108

YC4D105-D34

70

4/L

110*125

1950*850*1200

950

MST-80YIII

80

100

144

YC4D140-D31

100

4/L

108*115

2200*850*1200

1100

MST-90YIII

90

112.5

162

YC4D155-D31

103

4/L

108*115

2300*900*1500

1200

MST-100YIII

100

125

180

YC4A165-D30

110

4/L

108*132

2300*900*1500

1250

 

Key Specifications

Item

Configuration

Generator Type

Silent Diesel Generator

Power Range

Customizable according to project requirements

Fuel

Diesel

Frequency

50 Hz / 60 Hz

Voltage

Customizable

Phase

Single Phase / Three Phase

Cooling

Water-Cooled

Starting System

Electric Start

Controller

Intelligent Digital Controller

Enclosure

Sound-Attenuated Steel Canopy

Application

Prime / Standby Power

Output Connection

Customized to project requirements

 

product-600-600
product-600-600
product-600-600

 

Why the Silent Enclosure Matters

A diesel engine produces mechanical vibration, combustion noise, cooling-fan noise, and exhaust noise during operation.

The enclosure addresses these sources through acoustic insulation, airflow channels, vibration isolation, and controlled air intake and exhaust paths.

For a factory installed close to production offices, for example, reducing sound transmission can make a practical difference to the working environment. The operator hears the steady engine rhythm rather than the sharp mechanical noise of an exposed engine, while the steel canopy provides protection for the internal components.

The enclosure also protects the power system from dust, rain, and other outdoor conditions when the specified configuration is selected.

 

Available Configuration Options May Include

Engine:

Different diesel engine brands and power ratings

 

Alternator:

Multiple alternator configurations according to output requirements

 

Controller:

Digital control and monitoring systems

 

Fuel Tank:

Standard or extended-capacity designs

 

 

Canopy:

Silent, weather-resistant enclosure

 

Transfer System:

ATS configuration for automatic backup switching

 

Output:

Customized voltage, frequency, and connection requirements

 

Mobility:

Fixed, trailer-mounted, or project-specific configurations

 

 

For buyers preparing an RFQ, the following information helps suppliers select the correct configuration:
  • Required running load in kW or kVA
  • Motor starting loads
  • Prime or standby operation
  • 50 Hz or 60 Hz frequency
  • Required output voltage
  • Single-phase or three-phase supply
  • Indoor or outdoor installation
  • Required noise limit
  • Fuel tank operating time
  • Ambient temperature and installation altitude

 

If you want to know more about the heavy duty silent diesel generator, please contact us. We also provide support for foreign trade order coordination and offer prompt delivery.